H.P.W.® › Manifold accessories: valves, cabinets, pipe
H.P.W.® · accessories

Manifold accessories: valves, cabinets, pipe

Everything you need for a complete H.P.W.® manifold installation – 1" ball valves with thermometer, cabinets with adjustable height and depth, PEX-AL-PEX 16 × 2 pipe and EK compression fittings. Plus a stainless steel alternative for comparison.

updateUpdated: verifiedTechnically reviewed by the ATRIA SK s.r.o. technicians

valve1" ball valves with thermometerdoor_slidingFlush and surface-mounted cabinetsplumbingPEX-AL-PEX 16 × 2linkFittings 16 × 2 EK
checklistComplete assembly

Everything you need for the manifold

The H.P.W.® manifold is supplied as a complete assembly – with shut-off valves, regulating fittings with flow meters, an automatic air vent and a drain valve. To connect and install it, you need a few more parts: ball valves to isolate the whole manifold, compression fittings to connect the circuits, pipe for the floor with pipe clips or a system board, and a cabinet in which the manifold will be protected and accessible.

On this page you will find all these parts in one place, together with guidance on choosing the right size. Prices and availability on the product cards are loaded directly from the ATRIASHOP.EU online store. The manifolds themselves, from 2 to 12 circuits, can be found on the home page, and the installation procedure in the guide Installing and setting up the manifold.

fact_checkChecklist

Shopping list for one manifold

ItemPurposeCodeQuantity
H.P.W. manifolddistributing water to the circuits, control and air ventingROZDZ.02H – ROZDZ.12H1 pc (usually 1 per floor)
Ball valve with red butterfly handleflow isolation, 0–80 °C thermometerROZDZ.ZAW.CZ (straight) or ROZDZ.ZAW.K.CZ (angled)1 pc
Ball valve with blue butterfly handlereturn isolation, 0–80 °C thermometerROZDZ.ZAW.N (straight) or ROZDZ.ZAW.K.N (angled)1 pc
Compression fitting 16 × 2 EKconnecting the circuit pipes to the EK outlets500684 or RCS162 pcs per circuit
PEX-AL-PEX 16 × 2 pipeheating circuits in the floor and their supply sectionsPEXALPEX 162according to area and spacing
Pipe clip 75 mmfixing the pipe to the PPB insulation boardHPW01according to pipe length, packs of 50
System board with gridfloor insulation and pipe laying on a 10 × 10 cm gridUHP302FPaccording to area, 10 m² pack
Manifold cabinethousing and protecting the manifold1300HPX – 1350HPX (flush-mounted), 1210HPX – 1250HPX (surface-mounted)1 pc

Example: a manifold with 8 circuits needs 1 pair of ball valves and 16 compression fittings 16 × 2 EK. Pipe clips or a system board are chosen according to the laying method – you do not need both.

valveBall valves

1" ball valves with thermometer and regulating set

Ball valves are always fitted to the manifold as a pair – red on the flow, blue on the return. Choose the straight or angled version depending on where the pipe from the heat source comes from.

infoChoosing valves

Straight or angled ball valve?

H.P.W. ball valves are made of brass, have a 1" union connection and are screwed onto the end of the manifold with a 1" half-union fitting. Once they are fitted, you connect the pipe from the heat source to the free side of the valve. A ball valve opens and closes with a single quarter turn – compared with needle valves, for example, operation is quicker and more intuitive.

  • Straight valve – ROZDZ.ZAW.CZ and ROZDZ.ZAW.N. The connection continues in line with the manifold. Suitable when the pipe from the source comes from the side, for example from an adjacent room through the wall.
  • Angled valve – ROZDZ.ZAW.K.CZ and ROZDZ.ZAW.K.N. Turns the connection through 90°. Suitable when the pipe comes from below out of the floor or from above and there would be no room for a bend in the cabinet.

Built-in thermometer and colour coding

Each valve has a built-in thermometer with a 0–80 °C range, so you can see the water temperature on the flow and return right at the manifold without any additional measuring instruments. The difference between the two temperatures tells you how the system is releasing heat. The red butterfly handle marks the flow, the blue one the return – when operating the valves, it is immediately clear which side is open or closed.

Always as a pair

We recommend fitting both valves – on the flow and on the return – at the same time, so that the entire manifold can easily be isolated when needed. With a red valve, therefore, also order the matching blue valve of the same type. The T-KIT set with both colours in one pack is also available in the online store. Remember that ball valves add 85 to 90 mm to the length of the manifold assembly – take this into account when choosing a cabinet.

HPW Set2 regulating set for radiators

If the H.P.W. manifold supplies radiators with bottom connection, the good-value HPW Set2 regulating set is a practical choice. It contains an HPW HE Classic liquid-filled thermostatic head (order code 330001), an isolating VK valve for bottom-connected radiators EK × 1/2" in a straight (330004) or angled (330005) version, and two compression fittings for the pipe – 16 × 2 mm multilayer, 16 × 2 mm polybutylene (RCS16) or 15 × 2 mm polybutylene (RCS 15). You choose the valve and fitting versions when adding the set to your basket.

door_slidingCabinets

Manifold cabinets – flush-mounted and surface-mounted

A cabinet protects the manifold, hides the bundle of pipes and still keeps all valves and flow meters accessible. Manifold cabinets are either recessed into the wall (flush-mounted) or fixed to the wall (surface-mounted). All types in our range have a white enamel finish and a nickel-plated lock, and on every type the depth and height can be adjusted to suit the floor.

  • The flush-mounted cabinet (1300HPX – 1350HPX) is recessed into the wall, and its frame remains flush with the plaster. It is suitable for new builds and wherever the wall is thick enough. The height is adjustable within approximately 575–665 mm and the depth within 110–175 mm, or 120–186 mm for types 1310HPX and 1325HPX.
  • The surface-mounted cabinet (1210HPX – 1250HPX) is mounted on the wall surface. It is particularly suitable for retrofit installation, when you do not want to break into the masonry, or for thin partition walls. Dimensions: height 580 mm, depth 120 mm.

Each manifold requires a different cabinet size depending on its length. The decisive factor is the length of the H.P.W. manifold including ball valves, plus a reserve for connecting the flow and return and working with a spanner – recommended combinations can be found in the table below the products.

door_frontFlush-mounted

Flush-mounted cabinets 1300HPX – 1350HPX

Each card shows the largest H.P.W. manifold with ball valves that fits into the cabinet with a clearance of at least 100 mm for the connections.

door_backSurface-mounted

Surface-mounted cabinets 1210HPX – 1250HPX

For retrofit installation without breaking into the masonry. Height 580 mm, depth 120 mm; the height and depth at which the manifold sits can be adjusted to suit the floor.

straightenChoosing a cabinet

Which cabinet for the H.P.W.® manifold

The recommendation is based on the actual length of the H.P.W. manifold with ball valves and a clearance of at least 100 mm for connecting the pipes and working with a spanner.

Number of circuitsLength without ball valvesLength with ball valvesFlush-mounted cabinetSurface-mounted cabinet
2145 mm230 mm1300HPX1210HPX
3195 mm280 mm1310HPX1210HPX
4245 mm330 mm1310HPX1210HPX
5295 mm380 mm1320HPX1210HPX
6345 mm430 mm1320HPX1220HPX
7395 mm480 mm1325HPX1220HPX
8445 mm535 mm1325HPX1225HPX
9495 mm585 mm1325HPX1225HPX
10545 mm635 mm1330HPX1225HPX
11595 mm685 mm1330HPX1230HPX
12645 mm735 mm1340HPX1230HPX

If you install the manifold without ball valves, or with angled valves and pipes coming from below, a smaller cabinet may be sufficient – but always compare the length of the assembly with the width of the cabinet. For some types, the cabinet manufacturer points out that the usable internal width is approximately 50 mm less than the stated width. If you also plan to fit a pump or mixing group in the cabinet, refer to the “with pump” column in the table below.

table_chartManufacturer's data

Cabinet dimensions and capacity according to the manufacturer

The cabinet manufacturer's table gives an approximate number of circuits for a manifold without and with a pump group.

CabinetTypeWidth × height × depthCircuits without pumpCircuits with pump
1300HPXflush-mounted335 × 575–665 × 110–175 mm2, 3, 4–
1310HPXflush-mounted435 × 575–665 × 120–186 mm5, 6–
1320HPXflush-mounted565 × 575–665 × 110–175 mm7, 82, 3, 4
1325HPXflush-mounted715 × 575–665 × 120–186 mm9, 105, 6, 7
1330HPXflush-mounted795 × 575–665 × 110–175 mm11, 128
1340HPXflush-mounted965 × 575–665 × 110–175 mm13, 149, 10, 11
1350HPXflush-mounted1085 × 575–666 × 110–176 mm1512
1210HPXsurface-mounted485 × 580 × 120 mm5, 6–
1220HPXsurface-mounted615 × 580 × 120 mm7, 82, 3, 4
1225HPXsurface-mounted760 × 580 × 120 mm9, 105, 6, 7
1230HPXsurface-mounted845 × 580 × 120 mm11, 128
1240HPXsurface-mounted1015 × 580 × 120 mm13, 149, 10, 11
1250HPXsurface-mounted1125 × 580 × 120 mm15, 16, 17, 1812

The cabinet manufacturer's data are general and do not take into account the specific equipment of the manifold. For H.P.W. manifolds with ball valves, we recommend following the table above, which is based on their actual length.

ruleWhat to consider

How to choose a cabinet you won't regret

  1. Measure the whole assembly – the length of the H.P.W. manifold without ball valves is 145 mm for 2 circuits, and each additional circuit adds 50 mm. Ball valves add a further 85 to 90 mm. A manifold with 10 circuits and ball valves is therefore 635 mm long.
  2. Add space for the connections – the flow and return from the heat source have to be brought into the cabinet and connected. With straight ball valves you need room for a pipe bend next to the manifold; angled valves turn the connection downwards or upwards and save width.
  3. Think about the pump group – if the cabinet will also house a mixing unit with a pump, you need a considerably wider cabinet. Approximate values are given in the “with pump” column of the manufacturer's table.
  4. Check the depth – thermostatic heads and actuators on the return, as well as the ball valves, protrude in front of the manifold. The cabinet must be deep enough for the door to close.
  5. Height above the floor – set the bottom edge of the cabinet according to the finished floor height. The pipes must enter the floor from the manifold in a smooth bend, and there must be room below the lower bar for the fittings and a spanner.
  6. If in doubt, choose the larger one – the price difference is small compared with the work required to replace a cabinet built into the wall.

We will be happy to help you choose a cabinet for your specific assembly on our technical line +421 917 133 664 (Monday – Friday, 7:30 – 15:30 CET).

plumbingPipe and laying

Pipe, compression fittings, pipe clips and system board

The recommended pipe for H.P.W. manifolds is PEX-AL-PEX 16 × 2, connected with a compression fitting with an EK connection. The pipe is held in place with pipe clips or a system board with a grid.

layersTechnical details

Why PEX-AL-PEX 16 × 2 and how to lay it

PEX-AL-PEX 16 × 2 is a five-layer multilayer (plastic-aluminium) pipe. The inner and outer layers are made of cross-linked polyethylene (PEX), with a 0.2 mm aluminium foil between them. This combination brings together the advantages of metal and plastic pipes:

  • Oxygen barrier – the aluminium layer prevents oxygen from penetrating into the heating water. Oxygen would otherwise cause corrosion of the metal parts of the system – the boiler, the radiators and the pump.
  • Shape retention – the pipe holds its shape after bending and does not spring back like plain PEX. It can easily be routed around obstacles without additional fittings.
  • Low linear expansion – a coefficient of only 0.026 mm/m·K limits pipe movement when the temperature changes.
  • Smooth inner surface – a roughness of 0.007 mm means low pressure loss and resistance to limescale build-up.
  • Low wall thermal conductivity (0.45 W/m·K) limits heat loss through the pipe wall when distributing heating water.

The pipe can be joined with brass screw or press fittings. It is connected to the H.P.W. manifold with a compression fitting with an EK connection. The ALPEX 16 × 2 ALU-EK (500684) fitting is made of CW617N brass with an EPDM O-ring, rated PN 10 and up to +120 °C, and is tightened to 25–35 Nm. The RCS16 fitting with a 3/4" Eurocone connection is designed for both PEX-AL-PEX multilayer and polybutylene (PB) pipe with a diameter of 16 mm and is tightened to 30–40 Nm; besides manifolds, it is also suitable for return fittings, VK valves, thermostatic valves and regulating fittings with an EK connection. The rubber parts of both fittings must not be lubricated with mineral oils – only with a silicone-based lubricant.

Fixing the pipe

The HPW01 pipe clip (75 mm, bent design, made of ABS plastic) is used to fix underfloor heating pipe to the PPB thermal insulation base board. It is sold in packs of 50.

The UHP302FP system board is floor-grade polystyrene, 30 mm thick with a compressive strength of 100 kPa, covered with a laminated polypropylene fabric with a 10 × 10 cm grid. The grid makes it easier to lay the pipe at a precise spacing. The film overlaps by 2 cm on the longer side so that the joints can be taped during laying. The pipe is attached to the board with staples using a TACKER tool (HS or HS T staples, max. 50 mm long). The board is sold in full 10 m² packs.

If you need a different type of system board or a low-build underfloor heating solution, for example for a renovation, get in touch with us – we will be glad to advise you.

tuneSpecifications

Technical specifications of manifold accessories

Values according to the manufacturers' data and the product descriptions in the ATRIASHOP.EU online store.

ProductCodeSize / connectionOperating valuesMaterial and design
Straight / angled ball valve with thermometerROZDZ.ZAW.CZ, ROZDZ.ZAW.N, ROZDZ.ZAW.K.CZ, ROZDZ.ZAW.K.N1" with fitting, extends the assembly by 85–90 mmthermometer 0–80 °C, quarter-turn operationbrass, red (flow) or blue (return) butterfly handle
ALPEX 16 × 2 ALU-EK compression fitting500684Eurocone (EK) or M24PN 10, up to +120 °C, tightening torque 25–35 Nmbrass CW617N, EPDM O-ring (IVAR.TA 4420)
16 × 2 EK compression fittingRCS163/4" Eurocone (EK), 16 mm pipetightening torque 30–40 Nmfor PEX-AL-PEX and polybutylene (PB)
PEX-AL-PEX 16 × 2 pipePEXALPEX 16216 × 2.0 mm, inner diameter 11.9 mm, volume 0.113 l/mexpansion 0.026 mm/m·K, wall thermal conductivity 0.45 W/m·Kfive-layer, PEX + 0.2 mm aluminium (oxygen barrier)
PPB fixing clipHPW0175 mm, angledanchoring into the PPB insulation boardABS plastic, pack of 50 pcs
System board with gridUHP302FPthickness 30 mm, grid 10 × 10 cmhardness 100 kPapolystyrene with laminated PP fabric, pack of 10 m²
Flush-mounted cabinet1300HPX – 1350HPXwidth 335–1085 mm, height 575–665 mm, depth 110–175 (120–186) mmadjustable height and depthwhite enamel, nickel-plated lock
Surface-mounted cabinet1210HPX – 1250HPXwidth 485–1125 mm, height 580 mm, depth 120 mmadjustable mounting height and depthwhite enamel, nickel-plated lock

The H.P.W.® manifold itself has a 1" inlet and outlet connection, EK circuit outlets, a max. operating pressure of 6 bar, a max. temperature of +80 °C and a test pressure of 10 bar – details on the home page.

calculateConsumption

Pipe consumption and water content by spacing

Approximate calculation for PEX-AL-PEX 16 × 2 pipe (water content 0.113 l/m). The area per circuit assumes approximately 85 m of pipe in the floor, leaving a reserve for the supply section to the manifold.

Pipe spacingPipe per 1 m²Water content per 1 m²Area of one circuit (≈ 85 m)100 m circuit – water content
10 cm≈ 10 m≈ 1.13 l≈ 8.5 m²≈ 11.3 l
15 cm≈ 6.7 m≈ 0.76 l≈ 12.7 m²≈ 11.3 l
20 cm≈ 5 m≈ 0.57 l≈ 17 m²≈ 11.3 l

These are approximate values, excluding supply sections and cutting waste. Actual consumption depends on the shape of the room, the laying method and the length of the supply sections. The pipe spacing and the number of circuits are determined by the underfloor heating design; a guide to the number of circuits per room can be found on the home page.

compare_arrowsAlternative

Stainless steel manifolds as an alternative

In addition to H.P.W. brass manifolds, we also offer stainless steel manifolds for underfloor heating with 2 to 12 circuits. According to the manufacturer's documentation, they are made of stainless steel in accordance with the German standard DIN EN 1264-4:2009-11, and their country of origin is Germany. They can be used with all types of plastic pipe, including multilayer pipe, as well as with copper; the pipe is connected with a 3/4" EK fitting.

The stainless steel manifolds are equipped with dual-regulating flow meters with a flow indicator (Regolux 0–5 l/min) with memory function and with thermostatic valves with an M30 × 1.5 connection on each circuit, so every heating circuit can be controlled individually. Automatic air vents, rotating drain valves and nickel-plated brackets are included.

A side-by-side comparison of the brass and stainless steel versions can be found in the table below.

inventory_2Stainless steel

HR1103 stainless steel manifolds – 2 to 12 circuits

compareComparison

H.P.W.® brass or stainless steel – comparison

FeatureH.P.W. brass manifoldHR1103 stainless steel manifold
Materialbrass, Press-Messing Ms 58 fittings, nickel-platedstainless steel
Country of originSlovakia (ATRIA in-house production)Germany
Number of circuits2 to 122 to 12
Circuit connectionEK, Eurocone3/4" EK fitting
Flow meters0–5 l/min, dual-regulating, lockableRegolux 0–5 l/min with memory, dual-regulating
Return valvesintegrated thermostatic valvesM30 × 1.5 thermostatic valves
Air venting and drainingautomatic air vent (manual optional), drain valveautomatic air vents, rotating drain valves
Mountingaluminium bracket, quick mounting with brackets and screwsnickel-plated brackets
Operating valuesmax. 6 bar, +80 °C, test pressure 10 baraccording to the manufacturer's documentation
Custom assembly / OEMyes – air vent, ball valves, fittings to customer specification–

Both solutions are designed for underfloor heating with plastic or multilayer pipe and allow each circuit to be controlled individually. The choice depends mainly on the required material, the connection for heads and actuators, and the availability of a particular size.

balanceHow to decide

When to choose brass and when stainless steel

In terms of function, both types of manifold do the same job: they distribute water to the circuits, allow the flow rate of each circuit to be set and close it with the thermostatic valve on the return. The differences lie in the material, the design of the valves and the customisation options.

  • Choose the H.P.W. brass manifold if you want a product made in Slovakia with a compact width, quick mounting on an aluminium bracket and the option to configure the equipment – manual or automatic air vent, ball valves, fittings. An OEM version is also available for partners and system manufacturers.
  • Choose the HR1103 stainless steel manifold if the design or the client requires a stainless steel version, or if you want to use heads and actuators with an M30 × 1.5 connection.

Both types use the same PEX-AL-PEX 16 × 2 pipe and compression fittings with an EK connection. If you are not sure which manifold is more suitable for your installation, give us a call – we will advise you based on your specific project. Back to the H.P.W. manifold overview or to the guide Installation and setup.

thermostatControl

Heads, actuators and protection of the underfloor circuit

The H.P.W.® manifold has integrated thermostatic (return) valves on the lower bar – the return – one on each circuit. Thermostatic heads or actuators are fitted directly onto them. While the flow meter on the flow bar determines the maximum amount of water that can flow through a circuit, the valve on the return closes and opens the circuit as needed.

How to choose the controls

  • Thermostatic head – a cheap, maintenance-free solution, but it senses the temperature at the manifold, not in the room.
  • Actuator with room thermostat – the circuit closes when the required temperature is reached in the room. The most convenient and economical solution; actuators are made in normally closed and normally open versions. You will find room thermostats at avansa-europe.com – AVANSA® thermostats.
  • Connection – before buying a head or actuator, check that it matches the valve connection on the manifold. HR1103 stainless steel manifolds have thermoregulating valves with an M30 × 1.5 connection. If you are not sure, call us.

Mixing, pump and safety thermostat

If the heat source supplies water at a higher temperature than the floor can tolerate, a mixing circuit with its own heating circulation pump and an AVANSA TH 2A clamp-on safety thermostat (range 20–90 °C, 230 V, IP 20) belongs between the source and the manifold; it switches off the underfloor circuit pump if the set temperature is exceeded. During a power cut, a boiler backup power supply protects the boiler and pump. The detailed wiring and balancing procedure is in the guide Installing and setting the manifold.

warningWhat to watch out for

The most common mistakes when buying accessories

  • A cabinet with no reserve – the ball valves extend the manifold by 85–90 mm, and at least another 100 mm is needed to connect the flow and return. Choose using the table Which cabinet for the manifold, not by the length of the manifold alone.
  • Too little depth – thermostatic heads, actuators and ball valves protrude in front of the manifold. If the cabinet is shallow, the door will not close.
  • A single ball valve – valves always belong in a pair, red on the flow and blue on the return, otherwise the manifold cannot be isolated completely.
  • The wrong fitting – a 16 × 2 fitting belongs only on 16 × 2 mm pipe. Allow for two fittings per circuit.
  • Mineral oil on the O-ring – EPDM rubber parts may be lubricated only with a silicone-based lubricant.
  • Clips and board at the same time – HPW01 fixing clips and the system board with grid are two alternative ways of anchoring the pipe; you do not need both. The system board is sold only in whole packs of 10 m².
  • Pipe without an oxygen barrier – underfloor heating needs pipe with a barrier, for example PEX-AL-PEX 16 × 2 with a 0.2 mm aluminium layer.

You will find a manifold with the number of circuits you need in the overview of H.P.W.® manifolds.

helpFAQ

Questions about accessories

Do I have to buy ball valves as a pair?
Yes. Ball valves are always fitted to the manifold as a pair – one on the flow (red butterfly handle) and one on the return (blue butterfly handle). Only then can you isolate the entire manifold. The T-KIT set with both colours in one pack is also available.
Should I choose a straight or an angled ball valve?
A straight valve if the pipe from the source reaches the manifold from the side. An angled valve turns the connection through 90° and is suitable when the pipe comes from below out of the floor or from above and there is no room for a bend in the cabinet.
How many compression fittings do I need?
Two per circuit – one for the flow and one for the return. A manifold with 8 circuits therefore needs 16 fittings 16 × 2 EK (500684 or RCS16).
Surface-mounted or flush-mounted cabinet?
A flush-mounted cabinet is recessed into the wall with its frame flush with the plaster – ideal for new builds. A surface-mounted cabinet is fixed to the wall surface and is suitable for retrofit installations when you do not want to break into the masonry, or for thin partition walls.
Can the height and depth of the cabinet be adjusted?
Yes. On every cabinet type, both the depth and the height can be adjusted to suit the floor. Flush-mounted cabinets have a height adjustable within approximately 575–665 mm and a depth of 110–175 mm, or 120–186 mm for types 1310HPX and 1325HPX.
How do I choose a cabinet for the H.P.W. manifold?
Compare the width of the cabinet with the length of the manifold including ball valves (230 mm for 2 circuits up to 735 mm for 12 circuits) and leave a clearance of at least 100 mm for the connections. Recommended combinations are given in the table Which cabinet for the manifold on this page.
How much pipe do I need per 1 m² of floor?
Approximately 10 m at 10 cm spacing, 6.7 m at 15 cm spacing and 5 m at 20 cm spacing – excluding the supply sections to the manifold and waste. The exact consumption is determined by the system design.
Does PEX-AL-PEX pipe have an oxygen barrier?
Yes. The 0.2 mm aluminium layer between two layers of cross-linked polyethylene acts as an oxygen barrier and prevents oxygen from penetrating into the heating water, where it would cause corrosion of the metal parts of the system.
What is the difference between the 500684 and RCS16 fittings?
The 500684 (IVAR.TA 4420) is a compression fitting for ALPEX 16 × 2 multilayer pipe with a Eurocone or M24 thread, for PN 10 and up to +120 °C, tightened to a torque of 25–35 Nm. The RCS16 has a 3/4" Eurocone connection, suits PEX-AL-PEX and polybutylene pipe with a diameter of 16 mm and is tightened to a torque of 30–40 Nm. Both suit the outlets of the H.P.W.® manifold.
By how much do ball valves extend the manifold?
By 85 to 90 mm. An H.P.W.® manifold with 2 circuits is 230 mm long with ball valves, and with 12 circuits 735 mm. Use this length when choosing a cabinet and add a reserve of at least 100 mm for connecting the pipes.
Do I need both fixing clips and a system board?
No. HPW01 fixing clips are used to anchor the pipe into the PPB insulation board, while the UHP302FP system board with a 10 × 10 cm grid is used with staples for a TACKER tool. Choose one method according to the floor build-up.
Can the system board be bought by the square metre?
The price of the UHP302FP board is stated per 1 m², but it can only be ordered in whole packs of 10 m². When calculating the area you need, add an allowance for cutting waste and round up to whole packs.
Which heads and actuators fit the H.P.W.® manifold?
Heads and actuators are fitted onto the integrated thermostatic valves on the return of the manifold. Before buying, check that the head connection matches the valves – if you are not sure, call the technical line on +421 917 133 664. For HR1103 stainless steel manifolds the connection is M30 × 1.5.
Is PEX-AL-PEX 16 × 2 pipe also suitable for radiators and water distribution?
Yes. The five-layer PEX-AL-PEX 16 × 2 pipe is designed for hot and cold water distribution, radiator heating and underfloor heating. It is joined with brass screw or press fittings, and to the manifold with EK compression fittings.
Will a pump or mixing group also fit in the cabinet?
Yes, but you need a much wider cabinet. The number of circuits with a pump group is given in the “with pump” column of the manufacturer's table – for example, a flush-mounted 1330HPX or surface-mounted 1230HPX holds a manifold with 8 circuits and a pump. You will find pumps for the mixing circuit at avansa-europe.com.

H.P.W.® manifold accessories at ATRIASHOP.EU

Ball valves, cabinets, PEX-AL-PEX pipe, compression fittings, pipe clips and system boards with current prices and availability. We will be glad to advise you on choosing the right cabinet and assembly on our technical line +421 917 133 664 (Monday – Friday, 7:30 – 15:30 CET).

smart_displayVideo

Product videos

Short videos showing the products, installation and settings.

descriptionPDF

Manuals and documents to download

User manuals, technical data sheets and declarations of conformity for the products on this page (PDF).

support_agentATRIA

Have a question? Write to us

Our technician usually replies on the same working day.

call+421 917 133 664 · mailinfo@atria.sk

By sending you agree to the processing of your data for the purpose of replying. Privacy