Straight ball valve 1", red
- Typestraight
- Connection1" with union
- Thermometer0–80 °C
- Butterfly handlered
- Materialbrass
Everything you need for a complete H.P.W.® manifold installation – 1" ball valves with thermometer, cabinets with adjustable height and depth, PEX-AL-PEX 16 × 2 pipe and EK compression fittings. Plus a stainless steel alternative for comparison.
updateUpdated: verifiedTechnically reviewed by the ATRIA SK s.r.o. technicians
The H.P.W.® manifold is supplied as a complete assembly – with shut-off valves, regulating fittings with flow meters, an automatic air vent and a drain valve. To connect and install it, you need a few more parts: ball valves to isolate the whole manifold, compression fittings to connect the circuits, pipe for the floor with pipe clips or a system board, and a cabinet in which the manifold will be protected and accessible.
On this page you will find all these parts in one place, together with guidance on choosing the right size. Prices and availability on the product cards are loaded directly from the ATRIASHOP.EU online store. The manifolds themselves, from 2 to 12 circuits, can be found on the home page, and the installation procedure in the guide Installing and setting up the manifold.
| Item | Purpose | Code | Quantity |
|---|---|---|---|
| H.P.W. manifold | distributing water to the circuits, control and air venting | ROZDZ.02H – ROZDZ.12H | 1 pc (usually 1 per floor) |
| Ball valve with red butterfly handle | flow isolation, 0–80 °C thermometer | ROZDZ.ZAW.CZ (straight) or ROZDZ.ZAW.K.CZ (angled) | 1 pc |
| Ball valve with blue butterfly handle | return isolation, 0–80 °C thermometer | ROZDZ.ZAW.N (straight) or ROZDZ.ZAW.K.N (angled) | 1 pc |
| Compression fitting 16 × 2 EK | connecting the circuit pipes to the EK outlets | 500684 or RCS16 | 2 pcs per circuit |
| PEX-AL-PEX 16 × 2 pipe | heating circuits in the floor and their supply sections | PEXALPEX 162 | according to area and spacing |
| Pipe clip 75 mm | fixing the pipe to the PPB insulation board | HPW01 | according to pipe length, packs of 50 |
| System board with grid | floor insulation and pipe laying on a 10 × 10 cm grid | UHP302FP | according to area, 10 m² pack |
| Manifold cabinet | housing and protecting the manifold | 1300HPX – 1350HPX (flush-mounted), 1210HPX – 1250HPX (surface-mounted) | 1 pc |
Example: a manifold with 8 circuits needs 1 pair of ball valves and 16 compression fittings 16 × 2 EK. Pipe clips or a system board are chosen according to the laying method – you do not need both.
Ball valves are always fitted to the manifold as a pair – red on the flow, blue on the return. Choose the straight or angled version depending on where the pipe from the heat source comes from.





H.P.W. ball valves are made of brass, have a 1" union connection and are screwed onto the end of the manifold with a 1" half-union fitting. Once they are fitted, you connect the pipe from the heat source to the free side of the valve. A ball valve opens and closes with a single quarter turn – compared with needle valves, for example, operation is quicker and more intuitive.
Each valve has a built-in thermometer with a 0–80 °C range, so you can see the water temperature on the flow and return right at the manifold without any additional measuring instruments. The difference between the two temperatures tells you how the system is releasing heat. The red butterfly handle marks the flow, the blue one the return – when operating the valves, it is immediately clear which side is open or closed.
We recommend fitting both valves – on the flow and on the return – at the same time, so that the entire manifold can easily be isolated when needed. With a red valve, therefore, also order the matching blue valve of the same type. The T-KIT set with both colours in one pack is also available in the online store. Remember that ball valves add 85 to 90 mm to the length of the manifold assembly – take this into account when choosing a cabinet.
If the H.P.W. manifold supplies radiators with bottom connection, the good-value HPW Set2 regulating set is a practical choice. It contains an HPW HE Classic liquid-filled thermostatic head (order code 330001), an isolating VK valve for bottom-connected radiators EK × 1/2" in a straight (330004) or angled (330005) version, and two compression fittings for the pipe – 16 × 2 mm multilayer, 16 × 2 mm polybutylene (RCS16) or 15 × 2 mm polybutylene (RCS 15). You choose the valve and fitting versions when adding the set to your basket.
A cabinet protects the manifold, hides the bundle of pipes and still keeps all valves and flow meters accessible. Manifold cabinets are either recessed into the wall (flush-mounted) or fixed to the wall (surface-mounted). All types in our range have a white enamel finish and a nickel-plated lock, and on every type the depth and height can be adjusted to suit the floor.
Each manifold requires a different cabinet size depending on its length. The decisive factor is the length of the H.P.W. manifold including ball valves, plus a reserve for connecting the flow and return and working with a spanner – recommended combinations can be found in the table below the products.
Each card shows the largest H.P.W. manifold with ball valves that fits into the cabinet with a clearance of at least 100 mm for the connections.







For retrofit installation without breaking into the masonry. Height 580 mm, depth 120 mm; the height and depth at which the manifold sits can be adjusted to suit the floor.






The recommendation is based on the actual length of the H.P.W. manifold with ball valves and a clearance of at least 100 mm for connecting the pipes and working with a spanner.
| Number of circuits | Length without ball valves | Length with ball valves | Flush-mounted cabinet | Surface-mounted cabinet |
|---|---|---|---|---|
| 2 | 145 mm | 230 mm | 1300HPX | 1210HPX |
| 3 | 195 mm | 280 mm | 1310HPX | 1210HPX |
| 4 | 245 mm | 330 mm | 1310HPX | 1210HPX |
| 5 | 295 mm | 380 mm | 1320HPX | 1210HPX |
| 6 | 345 mm | 430 mm | 1320HPX | 1220HPX |
| 7 | 395 mm | 480 mm | 1325HPX | 1220HPX |
| 8 | 445 mm | 535 mm | 1325HPX | 1225HPX |
| 9 | 495 mm | 585 mm | 1325HPX | 1225HPX |
| 10 | 545 mm | 635 mm | 1330HPX | 1225HPX |
| 11 | 595 mm | 685 mm | 1330HPX | 1230HPX |
| 12 | 645 mm | 735 mm | 1340HPX | 1230HPX |
If you install the manifold without ball valves, or with angled valves and pipes coming from below, a smaller cabinet may be sufficient – but always compare the length of the assembly with the width of the cabinet. For some types, the cabinet manufacturer points out that the usable internal width is approximately 50 mm less than the stated width. If you also plan to fit a pump or mixing group in the cabinet, refer to the “with pump” column in the table below.
The cabinet manufacturer's table gives an approximate number of circuits for a manifold without and with a pump group.
| Cabinet | Type | Width × height × depth | Circuits without pump | Circuits with pump |
|---|---|---|---|---|
| 1300HPX | flush-mounted | 335 × 575–665 × 110–175 mm | 2, 3, 4 | – |
| 1310HPX | flush-mounted | 435 × 575–665 × 120–186 mm | 5, 6 | – |
| 1320HPX | flush-mounted | 565 × 575–665 × 110–175 mm | 7, 8 | 2, 3, 4 |
| 1325HPX | flush-mounted | 715 × 575–665 × 120–186 mm | 9, 10 | 5, 6, 7 |
| 1330HPX | flush-mounted | 795 × 575–665 × 110–175 mm | 11, 12 | 8 |
| 1340HPX | flush-mounted | 965 × 575–665 × 110–175 mm | 13, 14 | 9, 10, 11 |
| 1350HPX | flush-mounted | 1085 × 575–666 × 110–176 mm | 15 | 12 |
| 1210HPX | surface-mounted | 485 × 580 × 120 mm | 5, 6 | – |
| 1220HPX | surface-mounted | 615 × 580 × 120 mm | 7, 8 | 2, 3, 4 |
| 1225HPX | surface-mounted | 760 × 580 × 120 mm | 9, 10 | 5, 6, 7 |
| 1230HPX | surface-mounted | 845 × 580 × 120 mm | 11, 12 | 8 |
| 1240HPX | surface-mounted | 1015 × 580 × 120 mm | 13, 14 | 9, 10, 11 |
| 1250HPX | surface-mounted | 1125 × 580 × 120 mm | 15, 16, 17, 18 | 12 |
The cabinet manufacturer's data are general and do not take into account the specific equipment of the manifold. For H.P.W. manifolds with ball valves, we recommend following the table above, which is based on their actual length.
We will be happy to help you choose a cabinet for your specific assembly on our technical line +421 917 133 664 (Monday – Friday, 7:30 – 15:30 CET).
The recommended pipe for H.P.W. manifolds is PEX-AL-PEX 16 × 2, connected with a compression fitting with an EK connection. The pipe is held in place with pipe clips or a system board with a grid.





PEX-AL-PEX 16 × 2 is a five-layer multilayer (plastic-aluminium) pipe. The inner and outer layers are made of cross-linked polyethylene (PEX), with a 0.2 mm aluminium foil between them. This combination brings together the advantages of metal and plastic pipes:
The pipe can be joined with brass screw or press fittings. It is connected to the H.P.W. manifold with a compression fitting with an EK connection. The ALPEX 16 × 2 ALU-EK (500684) fitting is made of CW617N brass with an EPDM O-ring, rated PN 10 and up to +120 °C, and is tightened to 25–35 Nm. The RCS16 fitting with a 3/4" Eurocone connection is designed for both PEX-AL-PEX multilayer and polybutylene (PB) pipe with a diameter of 16 mm and is tightened to 30–40 Nm; besides manifolds, it is also suitable for return fittings, VK valves, thermostatic valves and regulating fittings with an EK connection. The rubber parts of both fittings must not be lubricated with mineral oils – only with a silicone-based lubricant.
The HPW01 pipe clip (75 mm, bent design, made of ABS plastic) is used to fix underfloor heating pipe to the PPB thermal insulation base board. It is sold in packs of 50.
The UHP302FP system board is floor-grade polystyrene, 30 mm thick with a compressive strength of 100 kPa, covered with a laminated polypropylene fabric with a 10 × 10 cm grid. The grid makes it easier to lay the pipe at a precise spacing. The film overlaps by 2 cm on the longer side so that the joints can be taped during laying. The pipe is attached to the board with staples using a TACKER tool (HS or HS T staples, max. 50 mm long). The board is sold in full 10 m² packs.
If you need a different type of system board or a low-build underfloor heating solution, for example for a renovation, get in touch with us – we will be glad to advise you.
Values according to the manufacturers' data and the product descriptions in the ATRIASHOP.EU online store.
| Product | Code | Size / connection | Operating values | Material and design |
|---|---|---|---|---|
| Straight / angled ball valve with thermometer | ROZDZ.ZAW.CZ, ROZDZ.ZAW.N, ROZDZ.ZAW.K.CZ, ROZDZ.ZAW.K.N | 1" with fitting, extends the assembly by 85–90 mm | thermometer 0–80 °C, quarter-turn operation | brass, red (flow) or blue (return) butterfly handle |
| ALPEX 16 × 2 ALU-EK compression fitting | 500684 | Eurocone (EK) or M24 | PN 10, up to +120 °C, tightening torque 25–35 Nm | brass CW617N, EPDM O-ring (IVAR.TA 4420) |
| 16 × 2 EK compression fitting | RCS16 | 3/4" Eurocone (EK), 16 mm pipe | tightening torque 30–40 Nm | for PEX-AL-PEX and polybutylene (PB) |
| PEX-AL-PEX 16 × 2 pipe | PEXALPEX 162 | 16 × 2.0 mm, inner diameter 11.9 mm, volume 0.113 l/m | expansion 0.026 mm/m·K, wall thermal conductivity 0.45 W/m·K | five-layer, PEX + 0.2 mm aluminium (oxygen barrier) |
| PPB fixing clip | HPW01 | 75 mm, angled | anchoring into the PPB insulation board | ABS plastic, pack of 50 pcs |
| System board with grid | UHP302FP | thickness 30 mm, grid 10 × 10 cm | hardness 100 kPa | polystyrene with laminated PP fabric, pack of 10 m² |
| Flush-mounted cabinet | 1300HPX – 1350HPX | width 335–1085 mm, height 575–665 mm, depth 110–175 (120–186) mm | adjustable height and depth | white enamel, nickel-plated lock |
| Surface-mounted cabinet | 1210HPX – 1250HPX | width 485–1125 mm, height 580 mm, depth 120 mm | adjustable mounting height and depth | white enamel, nickel-plated lock |
The H.P.W.® manifold itself has a 1" inlet and outlet connection, EK circuit outlets, a max. operating pressure of 6 bar, a max. temperature of +80 °C and a test pressure of 10 bar – details on the home page.
Approximate calculation for PEX-AL-PEX 16 × 2 pipe (water content 0.113 l/m). The area per circuit assumes approximately 85 m of pipe in the floor, leaving a reserve for the supply section to the manifold.
| Pipe spacing | Pipe per 1 m² | Water content per 1 m² | Area of one circuit (≈ 85 m) | 100 m circuit – water content |
|---|---|---|---|---|
| 10 cm | ≈ 10 m | ≈ 1.13 l | ≈ 8.5 m² | ≈ 11.3 l |
| 15 cm | ≈ 6.7 m | ≈ 0.76 l | ≈ 12.7 m² | ≈ 11.3 l |
| 20 cm | ≈ 5 m | ≈ 0.57 l | ≈ 17 m² | ≈ 11.3 l |
These are approximate values, excluding supply sections and cutting waste. Actual consumption depends on the shape of the room, the laying method and the length of the supply sections. The pipe spacing and the number of circuits are determined by the underfloor heating design; a guide to the number of circuits per room can be found on the home page.
In addition to H.P.W. brass manifolds, we also offer stainless steel manifolds for underfloor heating with 2 to 12 circuits. According to the manufacturer's documentation, they are made of stainless steel in accordance with the German standard DIN EN 1264-4:2009-11, and their country of origin is Germany. They can be used with all types of plastic pipe, including multilayer pipe, as well as with copper; the pipe is connected with a 3/4" EK fitting.
The stainless steel manifolds are equipped with dual-regulating flow meters with a flow indicator (Regolux 0–5 l/min) with memory function and with thermostatic valves with an M30 × 1.5 connection on each circuit, so every heating circuit can be controlled individually. Automatic air vents, rotating drain valves and nickel-plated brackets are included.
A side-by-side comparison of the brass and stainless steel versions can be found in the table below.











| Feature | H.P.W. brass manifold | HR1103 stainless steel manifold |
|---|---|---|
| Material | brass, Press-Messing Ms 58 fittings, nickel-plated | stainless steel |
| Country of origin | Slovakia (ATRIA in-house production) | Germany |
| Number of circuits | 2 to 12 | 2 to 12 |
| Circuit connection | EK, Eurocone | 3/4" EK fitting |
| Flow meters | 0–5 l/min, dual-regulating, lockable | Regolux 0–5 l/min with memory, dual-regulating |
| Return valves | integrated thermostatic valves | M30 × 1.5 thermostatic valves |
| Air venting and draining | automatic air vent (manual optional), drain valve | automatic air vents, rotating drain valves |
| Mounting | aluminium bracket, quick mounting with brackets and screws | nickel-plated brackets |
| Operating values | max. 6 bar, +80 °C, test pressure 10 bar | according to the manufacturer's documentation |
| Custom assembly / OEM | yes – air vent, ball valves, fittings to customer specification | – |
Both solutions are designed for underfloor heating with plastic or multilayer pipe and allow each circuit to be controlled individually. The choice depends mainly on the required material, the connection for heads and actuators, and the availability of a particular size.
In terms of function, both types of manifold do the same job: they distribute water to the circuits, allow the flow rate of each circuit to be set and close it with the thermostatic valve on the return. The differences lie in the material, the design of the valves and the customisation options.
Both types use the same PEX-AL-PEX 16 × 2 pipe and compression fittings with an EK connection. If you are not sure which manifold is more suitable for your installation, give us a call – we will advise you based on your specific project. Back to the H.P.W. manifold overview or to the guide Installation and setup.
The H.P.W.® manifold has integrated thermostatic (return) valves on the lower bar – the return – one on each circuit. Thermostatic heads or actuators are fitted directly onto them. While the flow meter on the flow bar determines the maximum amount of water that can flow through a circuit, the valve on the return closes and opens the circuit as needed.
If the heat source supplies water at a higher temperature than the floor can tolerate, a mixing circuit with its own heating circulation pump and an AVANSA TH 2A clamp-on safety thermostat (range 20–90 °C, 230 V, IP 20) belongs between the source and the manifold; it switches off the underfloor circuit pump if the set temperature is exceeded. During a power cut, a boiler backup power supply protects the boiler and pump. The detailed wiring and balancing procedure is in the guide Installing and setting the manifold.
You will find a manifold with the number of circuits you need in the overview of H.P.W.® manifolds.
Ball valves, cabinets, PEX-AL-PEX pipe, compression fittings, pipe clips and system boards with current prices and availability. We will be glad to advise you on choosing the right cabinet and assembly on our technical line +421 917 133 664 (Monday – Friday, 7:30 – 15:30 CET).
Short videos showing the products, installation and settings.
User manuals, technical data sheets and declarations of conformity for the products on this page (PDF).
Our technician usually replies on the same working day.
call+421 917 133 664 · mailinfo@atria.sk
All our brands, specialist websites and online stores in one place.